First, the fault phenomenon: The power-on indicator light does not turn on. Check the contents: Ensure that the power supply is properly connected, the circuit breaker is closed, and check for any phase loss in the three-phase power supply. Remedy: Reconnect the power supply and close the circuit breaker. Second, the fault phenomenon: The power indicator is normal, the fan is running, but the work indicator is off. Check the content: Verify if the start switch is in the correct position. Method of exclusion: If the start switch is in the start position but the system doesn’t operate, try switching it back and forth to reset. Third, the fault phenomenon: The work indicator is on, but the current and voltage cannot be adjusted. Check the contents: Confirm that the voltage limit, current limit, and steady voltage knob are set to the minimum position. Exclusion method: Adjust the knobs according to the plating process requirements to the appropriate positions. Fourth, the fault phenomenon: During operation, the current output suddenly stops, but the work indicator remains on. Check the content: Inspect the connection between the power output and the plating tank. Exclusion method: Replace or reconnect the cable if a disconnection is found. Fifth, the fault phenomenon: During operation, there is no current output, and the protection indicator flashes. Check the content: 1. Check if the working environment temperature is too high and whether the fan is operating normally. Exclusion method: Fix the fan failure and improve the ventilation conditions. Check the content: 2. Determine if the instantaneous overcurrent protection has been triggered. Method: Press the boot program to restart the machine and see if it operates normally. Check the content: 3. Ensure the input voltage is stable—check for overvoltage, undervoltage, or phase loss. Exclusion method: After fixing the power line issue, restart the system using the startup procedure. Check the content: 4. Inspect the power rectifier diodes for short circuits. Exclusion method: Replace the faulty rectifier diode. Check the content: 5. Check if the power device or input rectifier module is damaged. Exclusion method: Replace the same type of power device and check the drive circuit. If necessary, replace the input plating rectifier module. Sixth, the fault phenomenon: Even after following the normal operation procedure, the protection indicator still flashes. Check the content: 1. Check if the working environment temperature is too high and whether the fan is functioning properly. Exclusion method: Repair the fan and improve the ventilation. Check the content: 2. Determine if the instantaneous overcurrent protection is active. Method: Press the boot program to restart the machine and check if the power supply works correctly. Check the content: 3. Confirm that the input voltage is stable—no overvoltage, undervoltage, or phase loss. Exclusion method: After resolving the power distribution issue, restart the system using the correct startup procedure. Check the content: 4. Inspect the power rectifier for any short circuits. Exclusion method: Replace the rectifier if necessary. Check the content: 5. Evaluate the condition of the power device. Exclusion method: If the input rectifier module is damaged, replace it with the same model and check the drive circuit. If needed, replace the input plating rectifier module.

Switch Cabinet

Switch Cabinet,Innovative Low Voltage Switchgear Cabinet,Switch Rack Cabinet,Switch Cabinet Wall Mount

Tianhong Electric Power Technology Co., Ltd , https://www.tianhongtransformer.com